The Kenwood TS-50 is a compact HF transceiver covering 1.8-30 MHz with 100W output power, featuring built-in antenna tuner, DSP filtering, multiple operating modes (SSB, CW, AM, FM, FSK), and comprehensive front-panel controls. This service manual provides detailed technical information for maintenance, repair, and adjustment procedures.
Complete technical specifications and performance characteristics of the Kenwood TS-50 transceiver.
| Parameter | Specification |
|---|---|
| Frequency Coverage | 1.8-30 MHz (all amateur bands) |
| Output Power | 100W PEP (SSB), 100W (CW), 40W (AM) |
| Modes | USB, LSB, CW, AM, FM, FSK |
| Sensitivity | 0.16 μV for 10 dB S/N (SSB) |
| Selectivity | 2.4 kHz (SSB), 500 Hz (CW) |
| Power Supply | 13.8V DC ±15% |
| Current Drain | 22A max (transmit), 1.3A (receive) |
| Dimensions | 240W × 85H × 260D mm |
| Weight | 3.2 kg |
| Antenna Connector | SO-239 |
System block diagrams showing signal flow and major circuit sections.
NOTE: Refer to schematic diagrams for detailed circuit connections.
Detailed descriptions of major circuit functions and operation.
Step-by-step alignment and adjustment procedures using proper test equipment.
WARNING! Use calibrated test equipment and follow safety procedures.
Systematic troubleshooting procedures for common problems.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No power | Power supply, fuse, internal regulator | Check DC input, replace fuse F1 (8A), verify regulator IC |
| No transmit | PA stages, ALC circuit, PTT switch | Check PA transistors Q15-Q18, verify ALC voltage |
| Poor receiver sensitivity | RF amplifier, mixer, IF stages | Check Q1-Q3, verify mixer IC operation |
| Frequency error | PLL circuit, reference oscillator | Adjust TCXO X1, check PLL lock voltage |
| Display problems | LCD connector, contrast voltage | Check CN3 connection, adjust contrast pot |
Complete parts list with manufacturer part numbers and descriptions.
NOTE: Use only Kenwood genuine parts for critical components.
Printed circuit board layouts for all major assemblies.
Tip: Use magnifying glass for component identification.
Complete schematic diagrams for all circuit sections.
Mechanical assembly instructions and exploded views.
CAUTION! Handle PCBs carefully to avoid static damage.
Recommended test equipment for service and alignment.
| Equipment | Specification | Purpose |
|---|---|---|
| RF Signal Generator | 0.1-50 MHz, calibrated output | Receiver sensitivity tests |
| Power Meter | 0-200W, 1.8-30 MHz | Transmitter power measurement |
| Oscilloscope | 20 MHz bandwidth minimum | Waveform observation |
| Frequency Counter | 9-digit resolution | Frequency accuracy verification |
| Dummy Load | 50 ohm, 100W rating | Transmitter testing |
Important service notes and technical updates.
Service Support: Contact Kenwood technical support for latest service bulletins.